Battery Management
Circuit Protection
CZone™
DC and AC Monitoring
Electrical Accessories
Gas Detection
Lighting
Panels
Tank Level Monitoring
Obsolete Products
FAQ SKU:720-MDO-EP
Product Documents: |
Product Details:IntroductionThe Emergency Parallel function can be operated through a remotely mounted momentary switch or button. When activated, the 720MDO-EP is preprogrammed to remain in parallel mode for 10 minutes. At any time, by depressing and holding the momentary switch or button for 5 seconds, the emergency parallel activation will be cancelled. Manual Operation: The motorised operation of the 720-MDO-EP can be overridden at any time by depressing the Yellow Control Knob and turning clockwise towards the "Manual On" position or anticlockwise to the "Manual Off" position. If the 720-MDO-EP detects a manual override the LED will start flashing rapidly. LED Indications: a. Auto Mode: ON: EP is engaged Rapid Flash: On 0.1 Sec & off 0.1 Sec; b. Manual Mode: Specifications:Continuous Rating: 500 Amps DC
|