Product Catalogue

ULTRASONIC TANK SENDER

SKU:TS1

Product Details:

TS1 - BEP Ultrasonic Tank Sender - No Moving Parts

 

• Handles common outputs – 240-33, 10-180, Vetus 10-300
and 0-5 V tanks from BEP, Teleflex, Faria, VDO and many other
popular instrument brands. (When connecting to non-adjustable
gauges the TS1 must be pre-calibrated)
• Low Profile Design and standard SAE 5 hole mounting pattern,
allowing it to be retrofitted to practically all other sender brands.
• Can be set for tank dimensions via computer using BEP Marine’s
proprietary TS1 software, avoiding experimental tank filling on site
• Connects directly to the BEP 600-TLM-N digital tank monitor
when configured to a 0-5 V output
• Is set for 0-2000 mm depth off the shelf (not suitable for tank
depths less than 200 mm)
• Operating voltage: 10-32 V
• Current draw: 25 mA with 5 V gauge output
• Measurement method: Acoustic sonic measurement
• Tank depth: 0–2000 mm (6.5 ft)
• Accuracy Distance: 0–2000 mm (6.5 ft) at 2 mm accuracy
• Mounting: SAE 5 stud mounting pattern with gasket, seal and
screws (top mount only).
• Environmental temperature: 4–65 °C
• Chemical resistance: Petrol, diesel, water, toilet chemicals
• Tank type style: Metal and plastic with non linear capacity

• Works with petrol, diesel, fresh water, grey water and black waterTS1 Programming

 

USB Drivers:

For applications other than the standard settings, re-programming is necessary. Programming is a simple process and can be carried out by purchasing a programming kit, part no. TS1-PK and following the detailed instructions supplied.

Please go to "Tank Sender Software Downloads" to down load the applicable USB Drivers and Installation Instructions.

If you are not confident in carrying out your own programming, your supplier offers this service at an additional charge.

Please note, unless otherwise stated, the purchase price for the TS1 is for the standard configuration only, and does not include reprogramming.


BEP TS Programmer

BEP TS Programmer is a 32-bit Windows application used to pre-program the parameters of the TS1 ultrasonic tank sender via a computer COM port. These parameters are stored in the non-volatile memory in the tank sender and must be set correctly for TS1 to work with different tank shape, size and fluid type.

These parameters are classified into two categories:

  • Sensor Parameters
  • Linearisation Parameters

Screen Shot of TS1 programming Software.

Copyright © BEP Marine Ltd. All Rights Reserved
Web Design and Content Management by Benefitz